Elekta Geneva普遍的妇科Applicator

Modular without compromising - one applicator for most cervical cancer patients up to stage IIB

Easy to assemble and easy to insert, Geneva accommodates most female pelvic anatomies and is suitable for treating the majority of cervical cancer cases up to stage IIB. Offering distortion-free imaging and the option for guided interstitial brachytherapy with every configuration, Geneva provides unprecedented versatility without compromising ease of use and precision.

Geneva applicator is CE Marked and has U.S. FDA 510(k) clearance. Geneva is not available in some markets.

What's new

Unique features

  • Adaptable for a diverse patient population
  • Interstitial option always available
  • Precise treatment planning and accurate dose delivery
  • Easy to use in current clinical workflows

Essential features

  • Supports all image-guided BT treatments
  • Modular set-up, pick and choose system, individualized solution for each patient

Adaptable for a diverse patient population

For all centers doing Gyn brachy treatment


“Improvements made on this new applicator make its operation process more convenient. It also provides new options in smaller sizes for a wider range of clinical applications.”
Guanghui Cheng, MD, PhD, Head of Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, Changchun, China
learn more

Accommodates most female pelvic anatomies

Geneva can be configured to suit most female pelvic anatomies. From the smallest ovoid size (13 mm) to the largest (40 mm), the intrauterine tube is available in six different lengths (30 – 80 mm) and at three different angles (15°, 30°, 45°).

Interstitial option always available


Geneva ensures that the option for guided interstitial brachytherapy is always available, even with the smallest ovoids, for optimal target coverage.

Precise treatment planning and accurate dose delivery

Geneva is completely MR safe, offering distortion-free image guidance using all 2D and 3D imaging options.

From precise treatment planning to accurate delivery

learn more

Supports all image-guided BT treatments

Designed to be MR and CT safe. This give rigidity and will also set up for image guided adaptive brachytherapy (IGABT) due to interstitial option.

Fixed geometry for rapid Applicator Modeling in less than minutes

Fixed geometry, as other Elekta brachy applicators, reproducing dosimetry and do easier applicator reconstruction.

No compromise to flexibility

Spreading capablilty and allowing for wider reach. Providing a spread of Ovoid range of 15 mm to 40 mm (source to source) where even the smallest ovoids give a wider reach.

Create. Click.

Easy to use in current clinical workflows


Unique Elekta click system, ready for use in 4 clicks

使用独特的Elekta点击系统,应用cator is ready for use in just four clicks, ensuring a faster, more efficient workflow.

Modular set-up, pick and choose

The modular design is completely adaptable to suit patient needs and the innovative spreading clip ensures flexibility for a wider reach, if required. The applicator clamp is used to immobilize and stabilize the applicator once assembled.

Compatible with Elekta state-of-the-art platforms

Geneva is compatible with Oncentra Brachy treatment planning software and Elekta treatment delivery platforms.

Multifunctional spreading clip

learn more

Using the spreading clip to fix the applicator

learn more

Using the spreading clip to spread the ovoids

BrachyAcademy

Empowering through education


Peer-to-peer education platform for brachytherapy professionals

The BrachyAcademy comprises a complete peer-to-peer medical education library and includes programs such as clinical workshops and training visits to leading hospitals worldwide.

learn more BrachyAcademy